Could be tapes or the drive. In my op… PCs Windows 7 Storage Software Cloud Computing CrashPlan on Windows 8 Video by: Thomas The viewer will learn how to download, install and use CrashPlan from Code42.com on Share this post Link to post Share on other sites chasdrury 130 BMW 330d Members 130 1,949 posts Posted February 8, 2007 · Report post Thanks nordberg, will try that When all SCSI devices are external, the host adapter provides termination on one end, while an external terminator is attached to the last device on the external chain. http://deepfrom.com/unable-to/e3712-unable-to-close-session-ec-unrecoverable-data-error.html

If a tape drive was not cleaned according to the manufacturer’s recommendations, there could be build-up on the heads and a cleaning tape won’t be able to remove it. Petersburg GMT+03:00 :: Volgograd GMT+03:30 :: Tehran GMT+04:00 :: Abu Dhabi GMT+04:00 :: Baku GMT+04:00 :: Muscat GMT+04:00 :: Tbilisi GMT+04:00 :: Yerevan GMT+04:30 :: Kabul GMT+05:00 :: Ekaterinburg GMT+05:00 :: The owners manual for the drive gives the complete list of environmental factors that will case the drive to fail. Register a new account Sign in Already have an account?

E3712 Unable To Close Session

RE: Tape Engine SCSI Problems -- Have Debug Info vschumpy (Instructor) 12 Jan 06 15:46 I don't think you got the meaning of my post.The "Media Error [03]" is actually from If a device is set to the same SCSI ID as the adapter or another device, this will often cause "phantom" devices to be seen at IDs when there are no Could it be the tape drive? With active termination, you need to enable Termination Power on all devices.

If used more than specified, they will reach their end and not perform any cleaning. Join UsClose Jump to content Technology Corner TyreSmoke Existing user? SCAM: (SCSI Configures Auto Magically): Also known as Plug and Play for SCSI. It also includes configuration tips so your tape library runs at its best, as well as a glossary of terms.

Tags:Ca Arcserve backup v11.1server 2003 kevsws September 9, 2010 at 08:32:26 Specs: Windows Server 2003 Hi,We have Arcserve 11.1 SP4 installed on a Windows 2003 server, which for this particular backup Arcserve E6096 Bus length: Improper bus length can cause SCSI problems when external devices are connected. Report • #9 wanderer September 20, 2010 at 19:54:56 Thanks for posting back. https://www.experts-exchange.com/questions/25922202/Arcserve-E3713-unable-to-read-from-media-media-name-EC-UNRECOVERABLE-DATA-ERROR.html Comodo Backup is another solution for backing up your computer.

Join the community Back I agree Powerful tools you need, all for free. A tape changer that uses multiple IDs should have a lower ID than the tape drives installed in it. Report • #3 wanderer September 10, 2010 at 07:49:16 What does arcserve say the size of the backup on tape is?With no open file modules or not using shadow copy you Posted by Haik on 8 Jun 2004 6:34 Hi I have exactly teh same problem.

Arcserve E6096

Haik Message Edited by Haik on 02-25-2005 12:26 AM Like 0 Reply You have posted to a forum that requires a moderator to approve posts before they are publicly http://www.tyresmoke.net/forum/topic/87421-any-arcserve-gurus/ Hiya! E3712 Unable To Close Session This program is a Computer Associates soft. E3719 Unable To Write To Media SCSI OVERHEAD: The time it takes for the host adapter to internally process a SCSI command.

End-cap terminators have a single 50-pin Centronics male connector and attach to the open connector on the last device on the bus. PROGRAMMED INPUT/OUTPUT (PIO): A method of data transfer in which the host microprocessor transfers data to and from memory via the computer's I/O ports. TERMINATION: A device that attaches to both ends of an electrical bus and prevents reflection or echoes of signals that reach the end of the bus. If several types of errors (e.g. E6096 Media Error

Posted by Haik on 21 Aug 2004 6:55 Hi, I have done some research regarding to the ArcServ 6.61 backup software. Operating Systems ▼ Windows 10 Windows 8 Windows 7 Windows XP See More... That means the drive tried to write, failed, retried, failed, etc. have a peek at these guys RE: Tape Engine SCSI Problems -- Have Debug Info davidmichel (TechnicalUser) 14 Jan 06 21:47 Here is how it works.

The worst backup and restore utility known to man. Like 0 Reply You have posted to a forum that requires a moderator to approve posts before they are publicly available. Also in the mix is a Windows 2003 Server with Brightstor ARCserve Backup V. 11.5 SP3 (Build 4402) It's backing up to both tape and HDD currently, and I'm having trouble

So usually the text that is added by the ARCserve engineers is correct, in this case Write Error, but it is possible it could mean something else.

External devices have their own power supply and may temporarily lose enough power to cause a “Unit Attention” error. See below: Type Date Job Session Message ---------------------------------------------------------------------------------------------------- Information 2004/08/15 19:12:48 407 ** Summary forBKUP01 ** E3712 2004/08/15 19:12:47 407 Unable to close session. (EC=UNRECOVERABLE DATA ERROR) Information 2004/08/15 19:12:47 407 Talk With Other Members Be Notified Of ResponsesTo Your Posts Keyword Search One-Click Access To YourFavorite Forums Automated SignaturesOn Your Posts Best Of All, It's Free! My knowledge of tapes+drives is very limited and I do not know what is a reasonable life time expectation.

Share this post Link to post Share on other sites techieboy 0 TVR 350C Members 0 2,251 posts Posted February 6, 2007 · Report post Not something silly like Outlook What are your thoughts, folks? Its not permissions - if I backup the server in question part by part it seems to be fine and backups everything it should do! TARGET: The SCSI device attached to the adapter.

Mark Dymond July 20, 2015 13:12 Share Facebook Twitter LinkedIn Google+ Official comment Hi Thanks for posting your question? I ran a Quick Eras Plus on it before using it and the test failed. The jobs consistently fail, giving errors like the following: [02/16/2009-01:35:13 ,0,0,0,0,0,2,0,0,0] W3895 [02/16/2009-01:35:13 ,0,0,0,0,0,2,0,0,0] Unable to position media. (MEDIA=A-ADICGFS-MON- 2/16/09 [S/N: 000047], EC=NO DATA DETECTED) [02/16/2009-01:37:28 ,0,0,0,0,0,2,0,0,0] W3550 [02/16/2009-01:37:28 ,0,0,0,0,0,2,0,0,0] Failed Windows servers...

SCSI IDs: SCSI IDs 0 & 1 should be used only for hard drives unless the adapter's documentation advises otherwise. All rights reserved. Sign In Now Sign in to follow this Followers 0 Go To Topic Listing Technology Corner All Activity Home Random Area Technology Corner Any Arcserve Gurus? Verify the slots are bus master, since not all EISA, VESA Local Bus, and PCI slots are.

Subscribe to our monthly newsletter for tech news and trends Membership How it Works Gigs Live Careers Plans and Pricing For Business Become an Expert Resource Center About Us Who We I am currently backuping up section by section to try and narrow it down...! I always take media out of the scheme when they fail. Don’t leave any SCSI cables not connected to a device, even if they are terminated.

About Advertising Privacy Terms Help Sitemap × Join millions of IT pros like you Log in to Spiceworks Reset community password Agree to Terms of Service Connect with Or Sign up Tapes can vary in thickness, tension, and particle density and tape drives are designed to properly handle those differences without causing damage to themselves or the tapes. Tape drives have a Summary and a Detail tab on the right side. PORT I/O ADDRESS: A window through which software programs communicate commands to an installed host adapter board.

Share this post Link to post Share on other sites chasdrury 130 BMW 330d Members 130 1,949 posts Posted February 6, 2007 · Report post Thats what I have been That is an external USB drive whereas the drive at 901mb/min is an internal SATA. FAST SCSI: The term "FAST" is generally applied to a SCSI device that can do synchronous transfers at speeds in excess of 5 mb/s. Put scanners at the end of the SCSI chain.

Cancel Red Flag SubmittedThank you for helping keep Tek-Tips Forums free from inappropriate posts.The Tek-Tips staff will check this out and take appropriate action. All other trademarks or registered trademarks are the property of their respective owners. I found that I finally laid a lot of my random crashes to bed by creating a local user called "Arcserve" (for argument's sake) on the Arcserve server, and making it